Low Tension Air Circuit Breaker

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Zhejiang

  • Validity to:

    Long-term effective

  • Last update:

    2020-03-20 17:42

  • Browse the number:

    72

Send an inquiries

Company Profile

Yueqing Zhengyan Electric Appliance Co., Ltd.

By certification [File Integrity]

Contact:zhengyandainqi(Mr.)  

Email:

Telephone:

Phone:

Area:Zhejiang

Address:Zhejiang

Website:http://www.zhengyan-electric.com/ http://zhengyandainqi.ydboli.com/

Product details

              


EPRW3 series air circuit breaker (ACR) shall be suitable for the distribution system of AC 50Hz/60Hz,Rated current 200A~4000A,Rated insulation voltage 1140V and Rated service voltage AC400V,AC500V/690V,AC800V/1140V,which shall distribute power energy, protection circuits and power supply equipment against the damage of over-load, under-voltage, short-circuit and single-phase grounding, and also disconnect function. Air circuit breaker with multiple protection function shall fulfill high-accuracy selection protection against no power, which shall improve the reliability and security of power supply system.

Parameter

Model

Breaking capacity    Normal   High breaking

Rated current

Rated service voltage

Rated insulation voltage

Rated impulse withstand voltage

Number of poles

Rated current for N pole

Rated ultimate short-circuit breaking capacity

Rated operation short-circuit breaking capacity

Rated short-circuit withstand current

Breaking time

Closing time

Life(period)

Overall dimension:HxWxDmm

D no including busbar length



Our Certificate


our company

Unpacking

1. After unpacking the product, you should carefully read whether the parameter label matches the system (including the rated operating voltage of accessories such as intelligent controllers, undervoltage releases, shunt releases, closed electromagnets, and electric energy storage mechanisms);

2. Shake the circuit breaker to the "test" position, connect the power of the secondary circuit, and check whether the control accessories work normally;

3. After confirming that it is correct, shake the circuit breaker to the "connected" position and put it into operation.

maintain

1. The dust should be cleaned regularly to keep the insulation performance of the circuit breaker good;

2. Regularly check the contact system, especially after each short-circuit current is broken, check whether the arc extinguishing chamber is intact, whether the contacts are in good contact, and whether the connecting parts are loose;

After reaching the mechanical life, you should contact the manufacturer for maintenance.